PRODUCTS & SERVICES
   
 

AUTOMOTIVE ENGINEERING

   > Test benches / Testing equipment

   Devices

     > AC Dynamometers
     > Conditioning Devices

     Engine & Dyno Control Devices
       ADAC
       > EDC 4.0

     > BlowBy
     > Servomatic

   > TORNADO System

 

> INDUSTRIAL ENGINEERING

>
BUILDING FACILITIES

   
   

 

 

ADAC 1000

 
  Advanced data acquisition and control system  
 

 

  • High performance data acquisition system optimized for engine and vehicle testing

  • Control functions for standardized automotive testing cycles (ELR, ETC, etc.)

  • Programmable controllers

  • High quality hardware based on industrial PC


KS ADAC is the real-time subsystem (hard and software) providing measuring, controlling and reporting functions at test benches.


We have optimized the internal architecture and data processing capabilities for the special requirements for test bench engineering.


In combination with the KS Tornado graphical user interface  - a KS software package - we can provide powerful solutions optimized to your individual needs.


KS ADAC covers a wide range of applications from research and development to end of line testing.

 

KS ADAC features

  • Pentium 4 processor

  • 12 Mbit Profibus DP interface

  • 100 Mbit Ethernet interface

  • Präemptives Multitasking Betriebssystem  RTOS-32

  • Limit monitoring

  • Output of setpoint values in real time

  • Controller parameter sets are switchable during operation

  • The hardware components of the measurement system are connected via Profibus DP. Modular design allows optimization of processing speed and costs. Given the Profibus standard, any DP slave can be integrated in the system.

  • Data reduction: due to high sampling rates, a huge amount of measurement data is collected initially. Before processing it, we therefore analyse and filter the data according to the information required (e.g. frequency range, minimum, maximum, etc.) thus effectively reducing the volume.


Measurement channels

Analog input

Resolution19 bit
Accuracy 0.01%
Sample rate up to 1 kHz signals
Thermocouples, Pt 100

Voltage ±10 V
Current ± 20 mA, bridge


Analog output

Resolution19 bit
Accuracy 0.01%
Sample rate up to 1kHz signals
Voltage ±10 V
Current ±20 mA


Frequency input

Range 0.1 Hz - 1 MHz
Resolution 0.01 Hz
Accuracy 0.001%
Gate time 1 ms - 1 Hz


Frequency output

Range up to 40 Hz
Resolution 0.01 Hz
Accuracy 0.001%
Gate time 1 ms - 1 Hz


Counter

Frequency 100 kHz max.


Digital I/O

Potential free 5V, 24V